Wharfedale Pro Connect Series User Manual

Browse online or download User Manual for DJ controllers Wharfedale Pro Connect Series. Wharfedale Pro Connect Series User manual [en]

  • Download
  • Add to my manuals
  • Print
  • Page
    / 8
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Unpacking
All Wharfedale Pro products are fully
checked before leaving the factory.
After unpacking please inspect
cabinets for any physical damage.
Please retain the shipping carton if
possible and internal packing material
in case the unit needs to be returned. Please check as soon
as possible the unit is functioning. In the event of any damage
please contact your dealer immediately so that a written claim
for damages can be made.
Wharfedale Pro Limited Warranty*
Wharfedale Pro EVP-XPSeries loudspeaker systems are warranted
to be clear of manufacturing or materials defects for a period of
one year from the original date of purchase. In the event of
malfunction, contact your authorised Wharfedale Professional
dealer or distributor for information.
*Be aware that warranty details may differ from country to
country. Contact your dealer or distributor for information.
These terms do not infringe your statutory rights.
WHARFEDALE PRO EVP-XP SERIES
WARNING & SAFETY INSTRUCTIONS
Wharfedale Pro EVP-XP Series of Professional Sound Reinforcement Loudspeakers
1. READ INSTRUCTIONS carefully before operating this product.
2
.
RETAIN these instructions.
3. COMPLY WITH WARNINGS - All warnings and instructions for
this product should be adhered to.
4. WATER & MOISTURE
- This Wharfedale Pro unit should
not be used near liquids. If should not have liquids placed on or in
close proximity as there are DANGEROUS VOLTAGES
present.
5. VENTILATION/AIR FLOW: This Wharfedale Pro unit
should not have its heat sinks obstructed from air flow. It should
not be situated in a built-in installation that may hamper air flow to
the heat sinks. It should not be placed near heat sources.
6. POWER SUPPLY: This Wharfedale Pro unit should be only
connected to a power supply as stated on the unit. Power supply
cables should be routed where they will not be walked on or
pinched by objects placed adjacent or upon them.
7. ELECTRIC SHOCK: Care should be taken that the grounding
of this unit is NOT defeated. Do not use this units power cable
with an extension cable unless the pins can be fully inserted.
7. CABLES - Use quality screened cables for signal connections.
8.   RIGGING • SUSPENDING • MOUNTING
The rigging, suspension or mounting of this speaker system can
expose members of the public to serious health risks and even
death. UNDER NO CIRCUMSTANCES ATTEMPT TO RIG,
SUSPEND OR OTHERWISE MOUNT THIS SYSTEM UNLESS
YOU ARE FULLY QUALIFIED AND CERTIFIED TO DO SO BY
RELEVANT LOCAL, STATE AND NATIONAL AUTHORITIES.
ALL RELEVANT SAFETY REGULATIONS MUST BE
FOLLOWED. IF YOU ARE NOT PROPERLY QUALIFIED OR DO
NOT KNOW OF PERTINENT REGULATIONS, CONSULT
QUALIFIED PERSONNEL FOR ADVICE AND ASSISTANCE.
9. CAUTION: These professional loudspeaker systems are
capable of generating very high sound pressure levels. Use care
with placement and operation to avoid exposure to excessive
levels that can cause permanent hearing damage.
10. SERVICING - The user should not attempt to service this
product except that mentioned in this manual.
EVP-XP POWERED SERIES
PROFESSIONAL LOUDSPEAKER
USER MANUAL.
THIS USER MANUAL COVERS THE FOLLOWING MODELS:
EVP-X12P • EVP-X12PM • EVP-X15P • EVP-X15PM •
EVP-X215P
EVP-X15PB • EVP-X18PB Subwoofers
Page 1
Contents:
Page 1: Warning and Safety Instructions
Page 2: Specifications/Operating and Use
Page 3. Product Features/ EVP-X12PM/15PM Panel
Page 4: EVP-X18PB Rear Panel Diagram
Page 5: EVP-X15PB and EVP-X18PB Operation
Page 6: Single EVP-X18PB with Stereo Mid/High Active System and Stereo Active Sub and Mid/High System
Page 7: Stereo Passive Mid/High Speaker with Active Sub System and EVP-X15P/18PB Block Diagram
Page view 0
1 2 3 4 5 6 7 8

Summary of Contents

Page 1 - USER MANUAL

UnpackingAll Wharfedale Pro products are fullychecked before leaving the factory.After unpacking please inspectcabinets for any physical damage.Please

Page 2 - WHARFEDALE PRO EVP-XP SERIES

Model Name EVP-X12P EVP-X12PM EVP-X15P EVP-X15PM EVP-X215P EVP-X15PB EVP-X18PBSYSTEM TYPE 12” 2-way 12” 2 way monitor 15” 2-way 15” 2-way monito

Page 3

EVP-X12PM/15PM Panel & Description:1. Level control: The Level control adjusts the overall volume of the amplified signal.2. 5 band EQ: Use this F

Page 4

IAGLTD,HUNTING TON,UK123567 84WHARFEDALE PRO EVP-XP SERIESPage 4

Page 5 - EVP-X15/18PB:

EVP-X15/18PB:1. INPUT A & INPUT B CONNECTORS-These electronically balanced, XLR and 1/4 “ phone connectors accept input signal from line-level so

Page 6

WHARFEDALE PRO EVP-XP SERIESPage6 EVP- X15PEVP- X15PEVP- X15P EVP- X15PSINGLE EVP-X18PB WITH STEREO MID/HIGH ACTIVE SYSTEMSTEREO ACTIVE SUB AND MID/HI

Page 7 - Right Output

HPFHPFHPFHPFAABBOUTPUTBAINPUTPHASE0/180OUTPUTS A& BOUTPUTS A& BTHRU HIGH PASSSPKRLEVELINPUTSPKRLEVELINPUTHPFEQLPFLIMIT400WWHARFEDALE PRO EVP-

Page 8

WHARFEDALE PRO EVP-XP SERIESWharfedale International Limited, IAG House, Sovereign Court, Ermine Business Park, Huntingdon, Cambs, PE29 6XU England WH

Comments to this Manuals

No comments