SPECIFICATIONS - Titan™ 12D / 15D
System Type
Frequency Response (+/-3dB)
Low Frequency Driver (mm/in.)
High Frequency Driver
Exit Size (mm / inches)
Dispersion (H x V)
Amplifiers
Low Frequency (Class D)
High Frequency (Class D)
Electronic Crossover:
Crossover Frequency
Equalization:
Subsonic Filter
Amplifier Protection
Power On
Thermal
Low Line Voltage Shut Down
Driver Protection
DC Protection
Short Protection
Clip Limiter:
Limiter Indicator
Power Indicator
Titan™ 12 D
Active 12” 2-way Bi-Amplified
55-20kHz
305mm / 12”
Titanium Compression Driver
25mm / 1"
90° x 60°
24dB/octave Linkwitz-Riley
2.3kHz
High (±10dB) 10kHz Shelving
Low (±5dB) 100Hz Shelving
30Hz, Second -order filter
Power switch on / off mute
Amplifier shutdown, auto reset
60% Nominal line voltage
Independent LF and HF limiters
Yes
Yes
Turns on approx 250W output
Red LED
Green LED
Titan™ 15 D
Active 15” 2-way Bi-Amplified
50-20kHz
381mm / 15”
Titanium Compression Driver
25mm / 1"
90° x 60°
24dB/octave Linkwitz-Riley
1.8kHz
High (±10dB) 10kHz Shelving
Low (±10dB) 100Hz Shelving
30Hz, Second -order filter
Power switch on / off mute
Amplifier shutdown, auto reset
60% Nominal line voltage
Independent LF and HF limiters
Yes
Yes
Turns on approx 350W output
Red LED
Green LED
Rated 250W continuous, 500W Peak
Rated 350W continuous, 700W Peak
Rated 50W continuous, 100W Peak Rated 70W continuous, 140W Peak